How to disable or enable AIX native Multi-Path I/O (MPIO) for LUNs with Array Product PID with the vxmpio utility
Description
Previous procedures to disable AIX MPIO multipathing to allow VxVM-DMP multipathing control required multiple steps including the download and installation of ODM array definitions from the array vendor. .
Veritas now provides the vxmpio utility which will disable or enable MPIO for array specific LUNs.
What follows is a vxmpio-disable and vxmpio-enable procedure walkthrough of the vxmpio utility.
DEVICE TYPE DISK GROUP STATUS OS_NATIVE_NAME ATTR
emc0_0 auto:none - - online invalid hdisk1 -
emc0_1 auto:none - - online invalid hdisk2 -
emc0_2 auto:none - - online invalid hdisk3 -
emc0_3 auto:none - - online invalid hdisk4 -
emc0_4 auto:none - - online invalid hdisk5 -
emc0_5 auto:none - - online invalid hdisk6 -
emc0_6 auto:none - - online invalid hdisk7 -
emc0_7 auto:none - - online invalid hdisk8 -
emc0_8 auto:none - - online invalid hdisk9 -
emc0_9 auto:none - - online invalid hdisk10 -
ibm_ds8x000_0 auto:LVM - - LVM hdisk0 -
hdisk0 Available 30-T1-01 MPIO Other FC SCSI Disk Drive
hdisk1 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk2 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk3 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk4 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk5 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk6 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk7 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk8 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk9 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk10 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk11 Available 35-T1-01 MPIO Other FC SCSI Disk Drive
VxVM vxmpio ERROR V-5-2-5826 MPIO already disabled, model_name 'SYMMETRIX' already exists in ODM
Device: emc0_0
devicetag: emc0_0
type: auto
info: format=none
flags: online ready private autoconfig invalid
pubpaths: block=/dev/vx/dmp/emc0_0 char=/dev/vx/rdmp/emc0_0
guid: -
udid: EMC%5FSYMMETRIX%5F000192600969%5F6900C84000
site: -
Multipathing information:
numpaths: 1
hdisk1 state=enabled
<<<<<<<< VxVM see a single psuedo MPIO device path
Device: emc0_1
devicetag: emc0_1
type: auto
info: format=none
flags: online ready private autoconfig invalid
pubpaths: block=/dev/vx/dmp/emc0_1 char=/dev/vx/rdmp/emc0_1
guid: -
udid: EMC%5FSYMMETRIX%5F000192600969%5F6900C85000
site: -
Multipathing information:
numpaths: 1
hdisk2 state=enabled
<<<<<<<< VxVM see a single psuedo MPIO device path
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS
================================================================================
hdisk1 ENABLED(A) - emc0_0 emc0 fscsi1 -
hdisk2 ENABLED(A) - emc0_1 emc0 fscsi1 -
hdisk3 ENABLED(A) - emc0_2 emc0 fscsi1 -
hdisk4 ENABLED(A) - emc0_3 emc0 fscsi1 -
hdisk5 ENABLED(A) - emc0_4 emc0 fscsi1 -
hdisk6 ENABLED(A) - emc0_5 emc0 fscsi1 -
hdisk7 ENABLED(A) - emc0_6 emc0 fscsi1 -
hdisk8 ENABLED(A) - emc0_7 emc0 fscsi1 -
hdisk9 ENABLED(A) - emc0_8 emc0 fscsi1 -
hdisk10 ENABLED(A) - emc0_9 emc0 fscsi1 -
hdisk0 ENABLED(A) - ibm_ds8x000_0 ibm_ds8x000 fscsi0 -
SUBPATH DANAME DMNAME GROUP STATE
hdisk1 emc0_0 - - ENABLED
hdisk2 emc0_1 - - ENABLED
hdisk3 emc0_2 - - ENABLED
hdisk4 emc0_3 - - ENABLED
hdisk5 emc0_4 - - ENABLED
hdisk6 emc0_5 - - ENABLED
hdisk7 emc0_6 - - ENABLED
hdisk8 emc0_7 - - ENABLED
hdisk9 emc0_8 - - ENABLED
hdisk10 emc0_9 - - ENABLED
hdisk0 ibm_ds8x000_0 - - ENABLED
hdisk0 U9117.MMB.1017B7P-V6-C430-T1-W50050763090386B5-L0 MPIO Other FC SCSI Disk Drive
Manufacturer................IBM <<<<<<<<<<<< array source
Machine Type and Model......2107900 <<<<<<<<<<<< PID
Part Number.................
ROS Level and ID............2E323436
Serial Number...............75TK2710
EC Level....................
FRU Number..................
Device Specific.(Z0)........000005329F101002
Device Specific.(Z1)........82D
Device Specific.(Z2)........075
Device Specific.(Z3)........05510
Device Specific.(Z4)........
Device Specific.(Z5)........
Device Specific.(Z6)........
hdisk1 U9117.MMB.1017B7P-V6-C431-T1-W50000972080F2561-L0 MPIO Other FC SCSI Disk Drive
Manufacturer................EMC <<<<<<<<<<<<< array source
Machine Type and Model......SYMMETRIX <<<<<<<<<<<<< PID
Part Number.................
ROS Level and ID............35383734
Serial Number...............69C84000
EC Level....................`.i
FRU Number..................D0
Device Specific.(Z0)........000004329008100A
Device Specific.(Z1)........@
Device Specific.(Z2)........
Device Specific.(Z3)........
Device Specific.(Z4)........T.
Device Specific.(Z5)..........
hdisk11 U9117.MMB.1017B7P-V6-C435-T1-W50000972080F2524-L0 MPIO Other FC SCSI Disk Drive
Manufacturer................EMC <<<<<<<<<<<<< array source
Machine Type and Model......SYMMETRIX <<<<<<<<<<<<< PID
Part Number.................
ROS Level and ID............35383734
Serial Number...............69246000
EC Level........................i
FRU Number..................D0
Device Specific.(Z0)........000004329008100A
Device Specific.(Z1)........@
Device Specific.(Z2)........
Device Specific.(Z3)........
Device Specific.(Z4)........U.
Device Specific.(Z5)..........
DEVICE TYPE DISK GROUP STATUS OS_NATIVE_NAME ATTR
ibm_ds8x000_0 auto:LVM - - LVM hdisk0 -
Do not use vxmpio to unmanage MPIO controlled SAN root/boot disks. The vxmpio utility was not designed to handle SAN boot disks, the utility will be enhanced to report a user friendly error message going forward, until we can support it. Here we are disabling MPIO on EMC disks.
Running bosboot ..
bosboot: Boot image is 46917 512 byte blocks.
VxVM vxmpio INFO V-5-2-5828 Please reboot the machine to disable MPIO support for SYMMETRIX
hdisk0 Available 30-T1-01 MPIO Other FC SCSI Disk Drive <<<< IBM LVM LUN
hdisk1 Available 31-T1-01 Other FC SCSI Disk Drive <<<< EMC multi-device paths per LUN
hdisk2 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk3 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk4 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk5 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk6 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk7 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk8 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk9 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk10 Available 31-T1-01 Other FC SCSI Disk Drive
hdisk11 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk12 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk13 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk14 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk15 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk16 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk17 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk18 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk19 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk20 Available 35-T1-01 Other FC SCSI Disk Drive
hdisk21 Available 35-T1-01 Other FC SCSI Disk Drive
20
SUBPATH DANAME DMNAME GROUP STATE
hdisk18 emc0_0c8a - - ENABLED
hdisk7 emc0_0c8a - - ENABLED
hdisk19 emc0_0c8b - - ENABLED
hdisk8 emc0_0c8b - - ENABLED
hdisk20 emc0_0c8c - - ENABLED
hdisk9 emc0_0c8c - - ENABLED
hdisk21 emc0_0c8d - - ENABLED
hdisk10 emc0_0c8d - - ENABLED
hdisk12 emc0_0c84 - - ENABLED
hdisk1 emc0_0c84 - - ENABLED
hdisk13 emc0_0c85 - - ENABLED
hdisk2 emc0_0c85 - - ENABLED
hdisk14 emc0_0c86 - - ENABLED
hdisk3 emc0_0c86 - - ENABLED
hdisk15 emc0_0c87 - - ENABLED
hdisk4 emc0_0c87 - - ENABLED
hdisk16 emc0_0c88 - - ENABLED
hdisk5 emc0_0c88 - - ENABLED
hdisk17 emc0_0c89 - - ENABLED
hdisk6 emc0_0c89 - - ENABLED
hdisk0 ibm_ds8x000_0 - - ENABLED
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS
================================================================================
hdisk1 ENABLED(A) - emc0_0c84 emc0 fscsi1 -
hdisk12 ENABLED(A) - emc0_0c84 emc0 fscsi2 -
hdisk13 ENABLED(A) - emc0_0c85 emc0 fscsi2 -
hdisk2 ENABLED(A) - emc0_0c85 emc0 fscsi1 -
hdisk14 ENABLED(A) - emc0_0c86 emc0 fscsi2 -
hdisk3 ENABLED(A) - emc0_0c86 emc0 fscsi1 -
hdisk15 ENABLED(A) - emc0_0c87 emc0 fscsi2 -
hdisk4 ENABLED(A) - emc0_0c87 emc0 fscsi1 -
hdisk16 ENABLED(A) - emc0_0c88 emc0 fscsi2 -
hdisk5 ENABLED(A) - emc0_0c88 emc0 fscsi1 -
hdisk17 ENABLED(A) - emc0_0c89 emc0 fscsi2 -
hdisk6 ENABLED(A) - emc0_0c89 emc0 fscsi1 -
hdisk18 ENABLED(A) - emc0_0c8a emc0 fscsi2 -
hdisk7 ENABLED(A) - emc0_0c8a emc0 fscsi1 -
hdisk19 ENABLED(A) - emc0_0c8b emc0 fscsi2 -
hdisk8 ENABLED(A) - emc0_0c8b emc0 fscsi1 -
hdisk20 ENABLED(A) - emc0_0c8c emc0 fscsi2 -
hdisk9 ENABLED(A) - emc0_0c8c emc0 fscsi1 -
hdisk10 ENABLED(A) - emc0_0c8d emc0 fscsi1 -
hdisk21 ENABLED(A) - emc0_0c8d emc0 fscsi2 -
hdisk0 ENABLED(A) - ibm_ds8x000_0 ibm_ds8x000 fscsi0 -
Device: emc0_0c84
devicetag: emc0_0c84
type: auto
info: format=none
flags: online ready private autoconfig invalid
pubpaths: block=/dev/vx/dmp/emc0_0c84 char=/dev/vx/rdmp/emc0_0c84
guid: -
udid: EMC%5FSYMMETRIX%5F000192600969%5F6900C84000
site: -
Multipathing information:
numpaths: 2
hdisk12 state=enabled <<<<<<<<<<<<<<<<<<<
hdisk1 state=enabled <<<<<<<<<<<<<<<<<<<
/etc/vx/bin/vxmpio enable pid=< product_id >
Method error (/usr/lib/methods/ucfgdevice):
0514-062 Cannot perform the requested function because the
specified device is busy.
VxVM vxmpio ERROR V-5-2-5825 Failed to remove devices hdisk12
DEVICE TYPE DISK GROUP STATUS
ibm_ds8x000_0 auto:LVM - - LVM
hdisk1 deleted
hdisk2 deleted
hdisk3 deleted
hdisk4 deleted
hdisk5 deleted
hdisk6 deleted
hdisk7 deleted
hdisk8 deleted
hdisk9 deleted
hdisk10 deleted
hdisk11 deleted
hdisk12 deleted
hdisk13 deleted
hdisk14 deleted
hdisk15 deleted
hdisk16 deleted
hdisk17 deleted
hdisk18 deleted
hdisk19 deleted
hdisk20 deleted
hdisk21 deleted
Running bosboot ..
bosboot: Boot image is 46914 512 byte blocks.
VxVM vxmpio INFO V-5-2-5829 Please reboot the machine to enable MPIO support for SYMMETRIX
hdisk0 Available 30-T1-01 MPIO Other FC SCSI Disk Drive
hdisk1 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk2 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk3 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk4 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk5 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk6 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk7 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk8 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk9 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk10 Available 31-T1-01 MPIO Other FC SCSI Disk Drive
hdisk11 Available 35-T1-01 MPIO Other FC SCSI Disk Drive
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS
================================================================================
hdisk1 ENABLED(A) - emc0_0 emc0 fscsi1 -
hdisk2 ENABLED(A) - emc0_1 emc0 fscsi1 -
hdisk3 ENABLED(A) - emc0_2 emc0 fscsi1 -
hdisk4 ENABLED(A) - emc0_3 emc0 fscsi1 -
hdisk5 ENABLED(A) - emc0_4 emc0 fscsi1 -
hdisk6 ENABLED(A) - emc0_5 emc0 fscsi1 -
hdisk7 ENABLED(A) - emc0_6 emc0 fscsi1 -
hdisk8 ENABLED(A) - emc0_7 emc0 fscsi1 -
hdisk9 ENABLED(A) - emc0_8 emc0 fscsi1 -
hdisk10 ENABLED(A) - emc0_9 emc0 fscsi1 -
hdisk0 ENABLED(A) - ibm_ds8x000_0 ibm_ds8x000 fscsi0 -
(AIX)(c1062-p7701-mp4) /{4.EN_US}
Enabled hdisk1 fscsi1
Enabled hdisk1 fscsi2
Enabled hdisk10 fscsi1
Enabled hdisk10 fscsi2
NAME STATE[A] PATH-TYPE[M] DMPNODENAME ENCLR-NAME CTLR ATTRS
================================================================================
hdisk1 ENABLED(A) - emc0_0 emc0 fscsi1 -
hdisk2 ENABLED(A) - emc0_1 emc0 fscsi1 -
hdisk3 ENABLED(A) - emc0_2 emc0 fscsi1 -
hdisk4 ENABLED(A) - emc0_3 emc0 fscsi1 -
hdisk5 ENABLED(A) - emc0_4 emc0 fscsi1 -
hdisk6 ENABLED(A) - emc0_5 emc0 fscsi1 -
hdisk7 ENABLED(A) - emc0_6 emc0 fscsi1 -
hdisk8 ENABLED(A) - emc0_7 emc0 fscsi1 -
hdisk9 ENABLED(A) - emc0_8 emc0 fscsi1 -
hdisk10 ENABLED(A) - emc0_9 emc0 fscsi1 -
hdisk0 ENABLED(A) - ibm_ds8x000_0 ibm_ds8x000 fscsi0 -
Applies To
AIX environments with SAN array attached LUNs where native AIX MPIO multipathing is enabled.