Event ID 8390 - When installing a new version of Compliance or Discovery Accelerator (DA) on an older, supported version of Enterprise Vault
Problem
Event ID 8390 errors are thrown during the attempt to install a new version of Compliance Accelerator (CA) or Discovery Accelerator (DA) with an older version of Enterprise Vault installed on the CA or DA sever.
Error Message
Log Name: Veritas Enterprise Vault
Source: Enterprise Vault
Event ID : 8390
Level: ErrorDescription: The EnterpriseVault.DirectoryConnection object reported an error.
The procedure number is out of range. Internal references:
Error [0x800706d1]
{CDirectoryConnectionObject::EnumIndexVolumeSetsByArchiveEx}
V-437-8390
Cause
A mismatch between the Enterprise Vault (EV) binaries (i.e., exe and dll files) loaded on the CA/DA server and the primary EV Directory Service server can cause a communications issue that is reflected as a out of range error.
Solution
All servers with the EV binaries (i.e., exe and dll files) in an EV site must match both the major and minor versions in order for CA and DA to be installed and function properly. Confirm the EV binaries version that is installed on all EV servers and compare with the EV binaries version installed on the CA or DA server. To obtain the EV binaries version, look in the registry on all EV, CA, and DA servers. The path and value label to view are as follows:
- For a 64-bit operating system:
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\KVS\Enterprise Vault\Install\Version