Problem
client moved to new master server - backups fail with status 59, and host properties fails with invalid server
Error Message
/usr/openv/netbackup/bin/admincmd/bptestbpcd -client <16>bptestbpcd main: Function ConnectToBPCD() failed: 46 server not allowed access
Cause
created /usr/openv/netbackup/logs/bpcd on the client then ran /usr/openv/netbackup/bin/admincmd/bptestbpcd -client from the master server to get the error code listed.
Solution
Found in the bpcd log on the client that the connection from the master server was coming into the client from a different interface then the one already listed in the bp.conf. Added the alternate interface of the master server to the server list in the client's bp.conf
Applies To
master has multiple interfaces