Veritas Access Appliance 8.3 Upgrade Guide

Last Published:
Product(s): Appliances (8.3)
Platform: Veritas 3340,Veritas 3350,Veritas 3360
  1. Introduction
    1.  
      About the Access Appliance upgrade
    2.  
      About the supported software versions
    3.  
      Supported upgrade paths
    4.  
      Supported upgrade paths if continuous replication is configured
    5. About the preupgrade check
      1.  
        Error messages displayed during the preupgrade check
  2. Upgrading Access Appliance
    1.  
      Access Appliance upgrade overview
    2. Downloading the appliance software updates
      1. Downloading the software update using the UI
        1.  
          Downloading a software update from the Veritas Support website
      2. Downloading software updates using the Access Appliance shell menu
        1.  
          Downloading software updates directly to an Access Appliance node
        2.  
          Downloading software updates to an Access Appliance node using a client share
        3. Downloading software updates to an Access Appliance node using SCP
          1.  
            Installing OpenSSH
    3. Performing an upgrade pre-check
      1.  
        Running an upgrade pre-check using the UI
      2.  
        Running a pre-check from the appliance shell menu
    4. Completing pre-upgrade tasks
      1.  
        Performing manual preupgrade tasks
      2.  
        Performing preupgrade tasks when replication is configured
      3.  
        Considerations for Veritas Data Deduplication server if it is configured without WORM storage
    5. Performing an upgrade
      1.  
        Upgrading Access Appliance using the UI
      2.  
        Performing an upgrade from the appliance shell menu
    6. Completing post-upgrade tasks
      1.  
        Renewing internal certificate
      2.  
        Downloading and installing the required EEBs
      3.  
        Reconfiguring non-WORM Veritas Data Deduplication server
      4.  
        Increasing the Veritas Data Deduplication storage to 2.4 PiB
  3. Installing EEBs using the UI
    1.  
      About Access Appliance EEBs
    2.  
      Downloading EEBs
    3.  
      Installing EEBs
    4.  
      Rolling back EEBs
    5.  
      Removing EEBs

About the Access Appliance upgrade

Access Appliance supports the following upgrade methods:

  • Rolling upgrade and Parallel upgrade

    Use this method if the Access Appliance is configured and the appliance nodes are part of the Access cluster.

  • Node-by-node upgrade

    Use this method if the appliance nodes are in factory state.

Note:

The appliance nodes that are in Not in Access cluster state cannot be upgraded. You can reset a node to the default factory settings, and then upgrade the node.

Table: Upgrade methods

Upgrade method

Description

Rolling upgrade

During a rolling upgrade, each node in the Access cluster is upgraded successively without stopping the Access cluster. Rolling upgrade minimizes the service downtime.

Download the required upgrade package to one of the nodes in the cluster and upgrade the node where the upgrade package is downloaded. The upgrade process copies and installs the upgrade package to other nodes in the cluster. During the upgrade, services switch between the nodes to keep the Access Appliance online. The services are down only when the services switch between the nodes.

If upgrade fails on one of the nodes, the update is automatically rolled back on all the nodes in the cluster and the nodes are restored to their earlier version.

Note:

Rolling upgrade is not supported for a single-node configuration.

Parallel upgrade

During a parallel upgrade, both nodes in the cluster are upgraded and restarted simultaneously. The cluster services are down while the nodes are restarting.

Download the required upgrade package to one of the nodes in the cluster and upgrade the node where the upgrade package is downloaded. The upgrade process copies and installs the upgrade package to other nodes in the cluster. The services are down when the nodes are restarted.

If upgrade fails on one of the nodes, the update is automatically rolled back on all the nodes in the cluster and the nodes are restored to their earlier version.

Node-by-node upgrade

Warning:

Ensure that all the nodes are in factory state before you use this upgrade method.

Download the required upgrade package to each node, and then upgrade each node separately by installing the update on each of the nodes.

If the upgrade fails, the update is rolled back and the node is restored to its earlier version.