The Upgrade of 32bit Indexes to 64 bit Indexes Causes EVIndexVolumesProcessor.exe to Crash

Problem

EVIndexVolumesProcessor.exe may crash repeatedly when attempting to upgrade 32 bit (pre-EV10) indexes to 64 bit EV10 indexes.

Error Message

Type: Warning
Event: 40967
Source:  Enterprise Vault
Category: Index Move Task
Description: EV Index Volumes Processor - Restarting failed process.

The process has failed abnormally and will be restarted automatically.
V-437-40967


Type: Error
Event: 1000
Source: Application Error
Category: Application Crashing Events
Description:
Faulting application name: EVIndexVolumesProcessor.exe, version: 10.0.0.1316, time stamp: 0x4e1374cc
Faulting module name: mscorwks.dll, version: 2.0.50727.4963, time stamp: 0x4e15067f
Exception code: 0xc00000fd
Fault offset: 0x00000000002c746a
Faulting process id: 0x(null)
Faulting application start time: 0x(null)
Faulting application path: (null)
Faulting module path: (null)
Report Id: (null)
V-437-1000

Cause

In some instances a large number of deleted items within the affected archive, which are awaiting the expiry of the deleted item retention setting period before being permanently deleted, may cause EVIndexVolumesProcessor.exe to crash repeatedly when this process is called to perform an upgrade of a pre-EV10 index to an EV10 index.

Solution

This issue has been addressed in the following release:
 

Enterprise Vault 10.0.1 - Release Details
http://www.symantec.com/docs/TECH147787