What third party Object Identifiers (OID's) does CommandCentral Storage use for monitoring

Problem

It may be necessary to know what OID's CommandCentral uses to monitor devices. For example, if one needs to know what OID's CCS references for Cisco devices.

Solution

The vxas.mib file under /opt/VRTSccs/VRTSas/data will give you this information.

Here is a snippet of the Cisco OID table:

$obj    1.3.6.1.4.1.9   cisco   CISCO-SMI       0
$obj    1.3.6.1.4.1.9.1 ciscoProducts   CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.2 local   CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.3 temporary       CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.4 pakmon  CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.5 workgroup       CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.6 otherEnterprises        CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.7 ciscoAgentCapability    CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.8 ciscoConfig     CISCO-SMI       0       NC_LEAF
$obj    1.3.6.1.4.1.9.9 ciscoMgmt       CISCO-SMI       0
$obj    1.3.6.1.4.1.9.9.289     ciscoFcFeMIB    CISCO-FC-FE-MIB 0
$obj    1.3.6.1.4.1.9.9.289.1   ciscoFcFeObjects        CISCO-FC-FE-MIB 0
$obj    1.3.6.1.4.1.9.9.289.1.1 cffFcFeConfig   CISCO-FC-FE-MIB 0
 

 