The McData switch is not shown on 'Oblject' column on CCS.

Problem

The McData switch is not shown on 'Object' column on CCS 'Configured Devices Summary' screen even though it was discovered.

Error Message

-------------------------------------
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] McdataExp: Device 10.10.150.32 in normal state
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] McdataExp_Explore: exploring device 10.10.150.32 using CIM true
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] explore_cimom: Devices\10.10.150.32
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] cimom: 10.10.150.32
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] profile: Not found
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] Attempting to locate cimom info for Devices\10.10.150.32
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] Cimom SSL TrustStore set to : C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\CimomSMISCerts
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] HAL SMIS SSL TrustStore set to : C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\VRTShalSMISCerts
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] HAL SMIS SSL Certificate set to: VRTShalSMIScert.pem
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] HAL SMIS SSL Certificate Private Key set to: VRTShalSMIScert.key
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] GetConfDevices Devices\10.10.150.32: 10.10.150.32
8/28/2009 16:44:57.171 [McDataSwitchExplorer@mkscdlp03] No devices configured for this cimom 10.10.150.32
-----------------------------------
 

Cause

If the switch being added is already managed by any EFCM or other McDATA SMI Agent, then the switch will not get manageability, though this procedure says, switch addition successful.
This means, the switch is added to this SMI Agent’s discovery list and will get discovered when the current management application drops the manageability. So, ManageSwitch List procedure will not list down the newly added switch.
 

Solution

Add EFCM in SMI-S agent, instead of adding McData switch directly.


Applies To

CCStorage 5.1

Terms of use for this information are found in Legal Notices.

Search

Survey

Did this article answer your question or resolve your issue?

No
Yes

Did this article save you the trouble of contacting technical support?

No
Yes

How can we make this article more helpful?

Email Address (Optional)