Translation Notice
Please note that this content includes text that has been machine-translated from English. Veritas does not guarantee the accuracy regarding the completeness of the translation. You may also refer to the English Version of this knowledge base article for up-to-date information.
infoscale-rhel7_x86_64-Patch-7.4.1.2200
Patch
Critical
Abstract
This issue occurs when the CoordPoint agent is upgraded to 7.4.1 from any earlier version using a rolling upgrade. A field was added to the VXFEN driver structure due to which the client, VXFEN_IOC_GET_COORD IOCTL, fails.
Description
Platform: RHEL7
Patch Name: infoscale-rhel7_x86_64-Patch-7.4.1.2200
Sort ID : 15836
Patch ID:
VRTSvcsag-7.4.1.1600-RHEL7
VRTSvxfen-7.4.1.2200-RHEL7
* * * READ ME * * * * * * InfoScale 7.4.1 * * * * * * Patch 2200 * * * Patch Date: 2020-05-31 This document provides the following information: * PATCH NAME * OPERATING SYSTEMS SUPPORTED BY THE PATCH * PACKAGES AFFECTED BY THE PATCH * BASE PRODUCT VERSIONS FOR THE PATCH * SUMMARY OF INCIDENTS FIXED BY THE PATCH * DETAILS OF INCIDENTS FIXED BY THE PATCH * INSTALLATION PRE-REQUISITES * INSTALLING THE PATCH * REMOVING THE PATCH PATCH NAME ---------- InfoScale 7.4.1 Patch 2200 OPERATING SYSTEMS SUPPORTED BY THE PATCH ---------------------------------------- RHEL7 x86-64 PACKAGES AFFECTED BY THE PATCH ------------------------------ VRTSvcsag VRTSvxfen BASE PRODUCT VERSIONS FOR THE PATCH ----------------------------------- * InfoScale Availability 7.4.1 * InfoScale Enterprise 7.4.1 * InfoScale Storage 7.4.1 SUMMARY OF INCIDENTS FIXED BY THE PATCH --------------------------------------- Patch ID: VRTSvxfen-7.4.1.2200 * 3986554 (3986553) After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state. Patch ID: VRTSvcsag-7.4.1.1600 * 3996796 (3996795) After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state. DETAILS OF INCIDENTS FIXED BY THE PATCH --------------------------------------- This patch fixes the following incidents: Patch ID: VRTSvxfen-7.4.1.2200 * 3986554 (Tracking ID: 3986553) SYMPTOM: After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state. DESCRIPTION: This issue occurs when the CoordPoint agent is upgraded to 7.4.1 from any earlier version using a rolling upgrade. A field was added to the VXFEN driver structure due to which the client, VXFEN_IOC_GET_COORD IOCTL, fails. RESOLUTION: This hotfix addresses the issue by providing a global field to serve the purpose instead of adding a field to the VXFEN driver structure. Patch ID: VRTSvcsag-7.4.1.1600 * 3996796 (Tracking ID: 3996795) SYMPTOM: After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state. DESCRIPTION: This issue occurs when the CoordPoint agent is upgraded to 7.4.1 from any earlier version using a rolling upgrade. A field was added to the VXFEN driver structure due to which the client, VXFEN_IOC_GET_COORD IOCTL, fails. RESOLUTION: This hotfix addresses the issue by building the VRTSvcsag module with the updated VxFEN structure. INSTALLING THE PATCH -------------------- Run the Installer script to automatically install the patch: ----------------------------------------------------------- Please be noted that the installation of this P-Patch will cause downtime. To install the patch perform the following steps on at least one node in the cluster: 1. Copy the patch infoscale-rhel7_x86_64-Patch-7.4.1.2200.tar.gz to /tmp 2. Untar infoscale-rhel7_x86_64-Patch-7.4.1.2200.tar.gz to /tmp/hf # mkdir /tmp/hf # cd /tmp/hf # gunzip /tmp/infoscale-rhel7_x86_64-Patch-7.4.1.2200.tar.gz # tar xf /tmp/infoscale-rhel7_x86_64-Patch-7.4.1.2200.tar 3. Install the hotfix(Please be noted that the installation of this P-Patch will cause downtime.) # pwd /tmp/hf # ./installVRTSinfoscale741P2200 [<host1> <host2>...] You can also install this patch together with 7.4.1 base release using Install Bundles 1. Download this patch and extract it to a directory 2. Change to the Veritas InfoScale 7.4.1 directory and invoke the installer script with -patch_path option where -patch_path should point to the patch directory # ./installer -patch_path [<path to this patch>] [<host1> <host2>...] Install the patch manually: -------------------------- Manual installation is not recommended. REMOVING THE PATCH ------------------ Manual uninstallation is not recommended. SPECIAL INSTRUCTIONS -------------------- NONE OTHERS ------ NONE
Applies to the following product releases
This update requires
This patch is a platform support patch to enable support for Red Hat Enterprise Linux 7 Update 8 on InfoScale 7.4.1
Update files
|
File name | Description | Version | Platform | Size |
---|