Upgrading SC with non-default DB passwords

Article: 100045333
Last Published: 2016-10-05
Ratings: 0 0
Product(s): APTARE IT Analytics

Problem

The SC upgrader will encounter issues in running if the DB passwords have been altered from their defaults.

In this case you will receive errors like the following:

1/26/16 3:30 PM [exec] ERROR:
1/26/16 3:30 PM [exec] ERROR:
1/26/16 3:30 PM [exec] ORA-01017: invalid username/password; logon denied
1/26/16 3:30 PM [exec] ORA-01017: invalid username/password; logon denied
1/26/16 3:30 PM [exec]

Cause

Upgrading SC with non-default DB passwords

Solution

For SC 9 and prior: A parameter value must be changed prior to running the upgrader to resolve this issue.

The file to edit is <APTARE_HOME>/upgrade/ant/sc_upgrade.xml

The line to change is:


<property name="ropwd" value="aptaresoftware123" />


Change the "ropwd" line to match the current "aptare_ro" DB user's password.

Save your changes and then proceed with the upgrade as documented.


You will also need to modify /opt/aptare/portal/WEB-INF/classes/sprint-config-dal.xml (after running the upgrade)



<property name="password" value="aptaresoftware123"/> 


 

Applies To

All

Was this content helpful?